Hydrodynamic measurements
|
 |
Metrohm Autolab Rotating Disk Electrode (RDE) complete setup
- Compatible with 3 mm and 5 mm diameter disk electrodes, ideal for advanced electrochemical research with measurements under controlled hydrodynamic conditions
- Wide rotation speed range: 100 – 10000 rpm with 1 rpm resolution, manual or software integrated control
- Ultra clean and ultra-low noise achieved with frictionless liquid (Hg) contact ensuring pristine signal quality for sensitive experiments
- Seamlessly integrates with Metrohm cell vessels and other standard electrochemical cells.
- Complete setup includes: Motor controller, rotator, rotating disk electrode, and connection cable for integration with Autolab potentiostats
|
 |
Metrohm Autolab Rotating Ring Disk Electrode (RRDE) complete setup
- Ultra-low noise, and ultra-clean dual liquid (Hg) contact rotating electrode designed for precise measurements under controlled hydrodynamic conditions for in-situ detection of reaction intermediates in electrochemical reaction mechanism studies
- Wide rotation speed range: 100 – 10000 rpm with 1 rmp resolution, manual or software integrated control
- Fully compatible with any Autolab potentiostat/galvanostat equipped with a bipotentiostat (BA) module
- Seamlessly integrates with the Metrohm Autolab RRDE cell, specially designed for electrochemical measurements carried out in ultra-clean conditions
- Electrode materials: Platinum (Pt), Gold (Au), and Glassy Carbon (GC) disks with Platinum (Pt) ring; theoretical collection efficiency of 24.8%
- Complete setup includes: Motor controller, rotator, rotating ring disk electrode, and connection cable for integration with Autolab potentiostats
|
Localized electrochemical measurements
|
|
Sensolytics Scanning Electrochemical Microscope (SECM)
- Metrohm Autolab potentiostats hyphenated with Sensolytics SECM instruments enables localized measurements for monitoring the electrochemical activity of a sample surface in corrosion, batteries, electrocatalysis, biosensors, and other applications
- Integrated control of the Metrohm Autolab potentiostat within the Sensolytics software
- Compact and customizable system, upgradeable at any time
- Supports a wide range of techniques: Scanning Droplet Cell (SDC), Scanning Electrochemical Microscopy (SECM), Scanning Electrochemical Cell Microscopy (SECCM) with capillary-based techniques, high-resolution SECM with nanoelectrodes and constant-distance mode SECM (Option Shearforce) are available
- Advanced features such as software-based tilt compensation, AC-SECM, multidimensional techniques (EC methods at each grid point), localized photoelectrochemical methods
|
Multimode electrode with Hg-drop capability
|
 |
Metrohm Autolab 663 VA Stand
- Essential accessory for optimizing polarographic and voltammetric measurements from fundamental to specialized electroanalytical and trace analysis.
- Compatible with a wide range of electrodes such as the Hg-drop electrode (i.e., MME pro), rotating disk electrodes, and scTRACE Gold electrodes
- Software-controlled, seamlessly integrated with any Autolab workstation
- Complete setup includes: Multi-Mode electrode pro (MME), the Ag/AgCl reference electrode and a Glassy carbon auxiliary electrode for an adaptable and high-precision measurements with purge and stirring control
|
Faraday cage
|
 |
Autolab Faraday Cage
- Provides optimal electromagnetic interference (EMI) shielding for sensitive electrochemical experiments, especially when measuring small signals
- Effectively blocks unwanted interference signals, ensuring the integrity of your experimental results
- With earth terminal inside the cage for easy and direct grounding to your Autolab potentiostat
- Spacious design for corrosion cells, Autolab R(R)DE rotator, Autolab Optical bench to fit inside the large Faraday cage
- Available in 2 different sizes : (WxDxH) 38x21x38 cm3 or 38x30x60 cm3
|
General purpose electrochemical cells
|
 |
General purpose electrochemical cells
- Suitable for 2-, 3- or 4-electrode configurations
- Exchangeable borosilicate glass cell vessels, available in a wide range of volumes from 5 mL to 400 mL
- Cell vessels available with thermostatic jacket
- Fit up to 5 electrodes or accessories (e.g., thermometer, gas inlet, pH sensor etc.), directly in the standard lid (standard 14/15 conical joint size)
- Corrosion resistant support stand with rod for cell stability and adjustable height
- Direct fitting of the Autolab R(R)DE and RCE into the lid
- Fits in the large Autolab faraday cage
|
RRDE cell
|
 |
Metrohm Autolab RRDE cell for electrocatalysis
- Complete electrochemical cell designed for forced convection (hydrodynamic) experiments using the Metrohm Autolab R(R)DE rotators
- All components in contact with the electrolyte are removable and resistant to aggressive cleaning procedures, making the cell suitable for typical electrocatalysis experiments or sensitive interfacial electrochemistry measurements
- Fits in the large Autolab Faraday cage
- Complete cell includes: a glass vessel (300 mL) fitted with a thermostatic jacket for temperature control, lid with 7 standard 14/15 conical holes, counter and reference electrode, thermometer, and gas inlet
|
Cells for Screen Printed Electrodes (SPE)
|
 |
Metrohm DropSens cells for Screen Printed Electrodes (SPE)
- Electrochemical cells compatible with the Metrohm Dropsens Screen Printed Electrodes (SPE)
- Available for any type of SPEs and any applications, for measurements done in static or flow conditions
Smart design, low volume, accurate and convenient to use
|
Working electrodes
|
 |
Metrohm Autolab 3 mm disk electrodes
- Electrode tips with 3 mm active material disk in a PEEK shaft for the best chemical compatibility
- Available with different disk materials such as: Platinum (Pt), Gold (Au), Glassy Carbon (GC), Silver (Ag)
- Directly compatible with the Autolab RDE and RRDE rotators for hydrodynamic measurements (as rotating disk electrodes)
- Conveniently used in static conditions with a pin connector (M4) and a Metrohm electrode shaft with integrated 4 mm banana connector
|
|
|
Metrohm Autolab 5 mm disk electrodes
- Electrode tips with 5 mm active material disk and a PEEK shaft for the best chemical compatibility
- Available with different disk materials such as: Platinum (Pt), Gold (Au), Glassy Carbon (GC), Silver (Ag) and other metals. A blank shaft is also available which can be filled with your own material
- Directly compatible with the Autolab RDE and RRDE rotators (only for Pt, GC and Au) for hydrodynamic measurements (as rotating disk electrodes)
- Conveniently used in static conditions with a pin connector (M4) and a Metrohm electrode shaft with integrated 4 mm banana connector
|
|
Metrohm Autolab Ring-Disk electrodes
- Dual, ring-disk electrode with 5 mm active material disk (0.375 mm thick) and a concentric Platinum ring, separated by a 0.375 mm electrically insulated, leak-free gap
- Theoretical collection efficiency of 24.9%
- PEEK shaft material for the best chemical compatibility
- Available with different disk materials : Platinum (Pt), Gold (Au), or Glassy Carbon (GC)
- Directly compatible with the Autolab RRDE rotators for hydrodynamic ring-disk measurements
|
|
|
Microelectrodes
- Comprehensive range of microelectrodes for exploring fundamental electrochemical principles, developing novel sensors, or investigating complex biological systems
- Exceptional sensitivity, reduced Ohmic drop, enhanced mass transport, minimal sample volume, suitable for a broad range of electrochemical techniques
- Available in a wide range of materials (e.g., Pt, Au, Ag, Ir) and disk diameters (10, 25, 50, 100, 500 µm)
- Fit directly into the Metrohm electrode shaft with integrated 4 mm banana connector for convenient and precise connection to your potentiostat
- Due to the low measured current signals, the use of an Autolab Faraday cage is recommended for electrochemical measurements with microelectrodes
|
|
|
Electrochemical quartz crystal microbalance (EQCM) crystals
- Gold (Au) and Platinum (Pt) coated quartz electrodes with a 6 MHz resonance frequency for fundamental and applied electrochemical studies in many applications such as (bio)sensor development, plating, corrosion, among others
- Compatible with the Metrohm Autolab Electrochemical Quartz Crystal Microbalance module with 13.6 mm crystal and 6.7 mm electrode diameter
- Double-sided crystal design with integrated contacts on both sides, providing extended electrode lifetime and convenience
- High sensitivity with detection limits in the range of ng/cm2
|
|
|
Metrohm DropSens Screen Printed Electrodes (SPE)
- Screen-printed electrodes (SPEs) are manufactured by printing a wide variety of inks over different substrates allowing rapid on-site analysis with high reproducibility, sensitivity and accuracy.
- Disposable, single use sensors which eliminate the electrode maintenance
- Specially designed to work with microvolumes, provide a low-cost, miniaturized platform for electrochemical research in different fields such as (bio)sensors, electroanalytical, electrocalatysis and others
- Available with a wide range of materials, configurations and types
- Conveniently connected to the Autolab potentiostats by using dedicated adaptors
|
Counter (Auxiliary) electrodes
|
 |
Platinum sheet counter electrode
- Can be used as a counter electrode for most electrochemical measurements
- Consists of a thin platinum sheet (~1 cm² surface area), embedded into a glass shaft
- Highly inert, robust and easy to clean
- Integrated 4 mm banana connector for convenient and precise connection to your potentiostat
- Standard 14/15 conical fitting, fits directly into the Metrohm Autolab measurement cells without any additional adaptors
|
|
|
Metrohm Autolab EQCM compatible counter electrode
- Gold (Au) coil counter electrode specially designed for the Autolab EQCM cell
- Highly inert, simple, and easy to clean
- Connect your Autolab potentiostat cables through the 4 mm banana to alligator clip adaptors which are included with every potentiostat
|
|
Metrohm Autolab Rod electrodes
- Inert rod electrodes which can be used as counter electrodes in your electrochemical measurements
- 2 mm outer diameter rods available in GC, Pt, Au and Stainless Steel, in various lengths
- Connect directly to the Metrohm electrode shaft with standard 14/15 conical fitting and integrated 4 mm banana connector for convenient and precise connection to your potentiostat.
- When used with the Metrohm shaft, it fits directly into the Metrohm Autolab measurement cells without any additional adaptors
|
Reference electrodes
|
 |
Metrohm single-junction Ag/AgCl reference electrode
- General purpose, refillable, silver/silver chloride (Ag/AgCl) reference electrode with c(KCl) = 3 mol/L as reference electrolyte, suitable for aqueous applications
- Sigle junction with low impedance, low leakage ceramic diaphragm, with glass shaft material, suitable for most of the electrochemical measurements across various applications
- Integrated 4 mm banana connector for convenient and precise connection to your potentiostat
- Standard 14/15 conical fitting, fits directly into the Metrohm Autolab measurement cells without any additional adaptors
|
|
|
Metrohm double-junction Ag/AgCl reference electrode
- General purpose, refillable, silver/silver chloride (Ag/AgCl) reference electrodes suitable for aqueous and non-aqueous applications
- Double-junction with low impedance, low leakage ceramic diaphragm, with glass shaft material, suitable for electrochemical measurements sensitive to (external) ionic impurities
- Refillable and freely selectable reference and bridge electrolyte according to the application requirements
- Integrated 4 mm banana connector for convenient and precise connection to your potentiostat
- Standard 14/15 conical fitting, fits directly into the Metrohm Autolab measurement cells without any additional adaptors
|
|
Metrohm Autolab EQCM compatible Ag/AgCl reference electrode
- Silver/silver chloride (Ag/AgCl) mini reference electrode specially designed for the Autolab EQCM cell
- Saturated KCl gel electrolyte sealed in a glass shaft (not refillable) with ceramic diafragm, for low leakage purposes.
- Connect your Autolab potentiostat cables through the 4 mm banana connector directly attached to the reference electrode
|
Adaptors and connectors
|
 |
Adaptor cable for connecting Metrohm Dropsens SPEs to 4 mm banana connectors
- Flexible adapter cable to conveniently connect the Metrohm Autolab potentiostats to the Metrohm DropSens Screen Printed Electrodes (SPEs)
- 4 mm banana connectors are directly attached to the adapter cable to conveniently connect to any Autolab potentiostat cable
- Recommended when working with SPEs immersed in solution or when working with cells and flow-cells
|
|
|
Connector box for connecting Metrohm DropSens SPEs to 4 mm banana connectors
- Robust adapter box to conveniently connect the Metrohm Autolab potentiostats to the Metrohm DropSens Screen Printed Electrodes (SPEs)
- Integrated 4 mm banana connectors to conveniently connect any Autolab potentiostat cable
- Recommended when working with SPEs in microvolumes, i.e., by placing a drop of electrolyte over the electrode
|
|
Alligator clips
- Alligator clips directly attachable to the standard 4 mm banana connectors
- Convenient and precise connection of your Autolab potentiostat to electrodes with non-standard connection used in your electrochemical cell
- Available in 2 different sizes in red and black
|